<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-14 15-08-08
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
105.90 MHz 5/5, 52 dBuV RTL2
Pilot RDS Phase Difference
6.9 kHz 4.1 kHz -1 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
16 kHz 74 kHz 10106 3,1071
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
7,8 dBr 8,56 dBr 9,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RTL2 " F215 0 (No PTY) 1 0 1 2 15:08, 14.02.2025
RT
"RTL2, Le Son POP-ROCK "
AF EON
88.2, 89.1, 89.2, 90.1, 92.2, 92.4, 94.4, 95.9, 96.6, 97.3, 97.4, 98.0, 98.2, 98.3, 98.9, 99.3, 101.3, 103.2, 105.1, 105.3, 105.9, 106.0, 106.1, 106.9 MHz -
FM Scope Station: 105.90 MHz, signal: 5/5 (52 dBuV) Max at: 74 kHz MIN: 16 kHz % above 75 kHz: 3,1071 Acquired: 2025/02/14 15:07:04 Total samples: 10106 Equivalent time: 0:08:25 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000
FM Scope MAX: 9,1 dBr MIN: 7,8 dBr AVE: 8,56 dBr % above 10,0 dBr: 0,0 Last value: 8,4 dBr (2025/02/14 15:07:04) Station: 105.90 MHz, signal: 5/5 (51 dBuV) 15:00 15:01 15:02 15:03 15:04 15:05 15:06 15:07 0 50 100 Dev. MAX [kHz] 0 5 10 Pm [dBr] 0 5 Signal Quality